SIGMA 1-14 Microfuge

Sigma 1-14 microfuge

  SIGMA 1-14

Small microfuge for research, biotechnology and medical laboratory.

  • Bright LCD - Display
  • Large capacity 24 x 1,5 - 2,2 ml
  • Top speed 14.800 rpm (16.163 x g)
  • Rapid acceleration and deceleration
  • Low temperature increase during run
  • Easy handling, big buttons
  • Short and continuous run, 99 min. timer
  • Two acceleration and deceleration curves
  • Motorized lid lock
  • Maintenance-free induction drive motor

Sigma 1-14 Part. no.   10014 (230V, 50/60 Hz)
Sigma 1-14 Part. no.   10015 (100-120V, 50/60 Hz

Rotors, accessories & tubes for the SIGMA 1-14 centrifuge

Rotors

Order. no.

Description

Max. rpm

Max. rcf

12082

Angle rotor made of aluminum, 12 x 1,5/2,2 ml, for e.g. reaction vials no.15008, 15040, incl. polysulfone lid no.17882

14.800

15.183

12083

Angle rotor made of aluminum, 18 x 1,5/2,2 ml, for e.g. reaction vials no.15008, 15040, or 18 x 0,24/0,4 ml e.g. no.15014, (2 lines) incl. polysulfone lid no.17882

14.800

14.448 / 15.673

12084

Angle rotor made of Aluminum, 24 x 1,5/2,2 ml, for e.g. reaction vials no.15008, 15040, incl. polysulfone lid no.17882

14.800

16.163

12092

Angle rotor made of polypropylene, 12 x 1,5/2,2 ml, for e.g. reaction vials no.15008, 15040, incl. polysulfone lid no.17882

14.800

15.183

12093

Angle rotor made of polypropylene, 18 x 1,5/2,2 ml, for e.g. reaction vials no.15008, 15040, order 18 x 0,24/0,4 ml e.g. no.15014, (2 lines) incl. Polysulfone no.17882

14.800

14.448 / 15.673

12094

Angle rotor made of polypropylene, 24 x 1,5/2,2 ml, for e.g. reaction vials no.15008, 15040, incl. polysulfone lid no.17882

14.800

16.163

11026

Microhematocritrotor, suitable for 24 capillary tubes Ø 1,4 x 50 mm, 35 µl no.15028, incl. reader no. 17028, usable with reader no.17026

13.000

11.903

12085

Angle rotor aluminum 16 x 1.5/2.2 ml or 16 x 0.5/0.7 ml

14.800

15.672

Accessories

Order. no.

Description

Suitable for:

13000

Adapter for reaction vials 0,25/0,4 ml no.15014

12082/12083/12084
12092/12093/12094

13002

Adapter for reaction vials 0,5/0,7 ml, Ø 7,9/10 x 28/31 mm no.15005

12082/12083/12084
12092/12093/12094

13021

Adapter for PCR-tube 0,2 ml

12082/12083/12084
12092/12093/12094

17882

Spare polysulfone lid for Angle rotors of Sigma 1-14

12082/12083/12084
12092/12093/12094

17026

Reader for use with microhematocritrotor

11026

17005

Capillary tube sealing putty (6 plates)

11026

Tubes

Order. no.

Description

Suitable for:

15028

Microhematocrit capillary tubes, heparin zed, 35 µl, Ø 1,4 x 50 mm, 200 pcs. per pack

11026

15014

Reaction-vials made of polypropylene 0,4 ml, 100 pcs. per pack

13000/12083/12093

15005

Reaction-vials 0,5 ml, 100 pcs. per pack

13002

15008

Reaction-vials 1,5 ml, 100 pcs. per pack

12082/12083/12084
12092/12093/12094

15040

Reaction-vials 2,2 ml, 100 pcs. per pack

12082/12083/12084
12092/12093/12094

Technical specifications SIGMA 1-14

Electric supply

230 V, 50/60 Hz; 100-120 V, 50/60 Hz

Power consumption, induction drive motor

95 W

Acceleration and deceleration curves

2

Max. rotational [1/min]

14.800

Min. rotational [1/min]

200

Max. capacity [ml]

24 x 2,2

Max. gravitational

16.163 x g

Min. gravitational

2 x g

Max. temp. increase rotor 12092
20 min / continuous run

9°C / 13°C

Max. tem. increase rotor 12092
20 min / continuous run

10°C / 11,1°C

Max. acceleration rotor 12092

13 sec.

Max. acceleration rotor 12094

14 sec.

Max. deceleration rotor 12092

11 sec.

Max. deceleration rotor 12094

12 sec.

interference suppression

EN 61326

Dimensions: height x width x depth [mm]

176 x 226 x 212

Weight without rotor [kg]

5,4

Noise level at max. speed

< 60 dB

Max. kinetic energy [Nm]

1721

Technical Services

  • BLOOD STORAGE COMPLIANCE SPECIALISTS

Let our specialist team of engineers guide your blood bank to MHRA compliance.

  • TEMPERATURE MAPPING
  • REFRIGERATION MAINTENANCE/SERVICING {24 HOUR/365 DAYS PER YEAR}
  • CALIBRATION CERTIFICATION
  • ALARM SYSTEM VERIFICATION
  • GLP COMPLIANT PAPER TRAIL

C&M Scientific offer a total packaged solution for blood bank equipment compliance to MHRA requirements, using the latest calibration and mapping equipment.

To overcome the issue of -34 plasma freezer calibration and verification of alarms, we have purchased the new Ametek "JOFRA ATC-125" calibration bath (operating to -90 oC). This equipment is essential and the only sure way to achieve compliance.

Biostore

  • "The safest way to store your temperature critical samples" 
  •  Offering the widest possible range of temperature controlled storage
  • Repository based in central Scotland 
  • Secondary Site Storage
  • Use as part of your business risk planning
  • Reduce your footprint in  storage
  • Storing your valuable materials with confidence

Product Sales

We offer equipment that is guaranteed to beat any quote on price/delivery and service backup. Contact our Sales department on 08452 608601 for an unbeatable quote.

HP / Credit terms available

  • ULT FREEZERS
  • C02 INCUBATORS
  • GROWTH CABINETS
  • WATER BATHS
  • TEMPERATURE MONITORING SYSTEMS
  • COOLED INCUBATORS
  • PLASMA FREEZERS
  • BLOOD FRIDGES
  • PLASMA FREEZERS
  • COLDROOMS
  • CENTRIFUGES
  • OVENS
  • CONSTANT TEMPERATURE ROOMS
  • ENVIRONMENTAL TEST CHAMBERS
  • WATER PURIFICATION SYSTEMS
  • LIQUID NITROGEN
  • OXYGEN MONITORS
  • TEMPERATURE MONITORING SYSTEMS {PART II COMPLIANT}
  • SHAKERS
  • CLASS II HOODS