Sigma benchtop centrifuge 2-16
SIGMA 2-16
SIGMA Benchtop Centrifuge 2-16
- Universal laboratory centrifuge for swing-out and angle rotors.
- For sedimentation up to 4 x 100 ml in swing-out rotors or up to 20 000 x g in angle rotors.
- Maintenance-free brushless drive motor.
- Simple 2-knob preselection of speed, time and rotors, with indication of these datas, imbalance and rotors.
- A magnetic rotor identification prevents rotors from overspeeding.
- Softstart an Softstop.
- Double lid locking device with latches according to VBG 7z.
- Stainless steel centrifuge chamber for optimal safety. Produced according to national and international safety regulations (e.g. IEC 1010, CE).
- No. 10145 for 230 V 50+60 Hz
- No. 10146 for 120 V 60 Hz
- No. 10147 for 100 V 50+60 Hz
Rotors & Accessories for the SIGMA 2-16 centrifuge
Rotors
|
Order. no.
|
Description
|
Max. rpm
|
Max. rcf
|
|
11124
|
Swing-out rotor 24 x 2,2 - 1,5, e.g. Eppendorf reaction vials no. 15008, 15040, incl. hermetic lid
|
12.000
|
12.927
|
|
12148
|
Angle rotor 24 x 2,2 - 1,5 ml, e.g. Eppendorf reaction vials no. 15008, 15040, incl. hermetic lid
|
15.000
|
20.630
|
|
12141
|
Angle rotor 10 x 10 ml, for tubes no. 15000, 15010, 15019 incl. hermetic lid
|
13.500
|
15.490
|
|
12139
|
Angle rotor 6 x 30 ml, for tubes no. 15029, 15030, 15032, 15024 , incl. hermetic lid
|
13.500
|
15.890
|
|
12151
|
Angle rotor 6 x 50 ml Falcon, for tubes no. 15151, incl. hermetic lid
|
7.800
|
6.462
|
|
11190
|
Swing-out rotor 4 x 100 ml complete, no. 11192, incl. buckets no. 13097, 4 glass tubes 100 ml no. 15100 and rubber cushions no. 16051
|
4.500
|
3.060
|
|
11191
|
Swing-out rotor 16 x 15 ml complete, no. 11192, incl. carriers no. 13012, 16 PS-tubes no. 15020 and rubber cushions no. 16015
|
4.500
|
3.030
|
|
11192
|
Swing-out rotor, without buckets
|
4.500
|
3.060/3.030
|
|
11122
|
Swing-out rotor for 2 to 6 microtiterplates
|
3.000
|
1.107
|
|
11123
|
Swing-out rotor for 2 to 6 microtiterplates
|
4.000
|
2.129
|
|
12107
|
Angle rotor, hermetically sealed for 12 PCR-Stripes with 8 tubes 0,2 ml
|
14.000
|
18.745/21.475
|
Accessories
|
Order. no.
|
Description
|
Suitable for:
|
|
13150
|
Bucket with screw cap for 1 Falcontube 50 ml no. 15151
|
11192
|
|
13060
|
Adapter for 1 Falcontube 15 ml no. 15115
|
12151, 13150
|
|
13040
|
Bucket with screw cap, max. length of tubes 110 mm, for round carriers no. 17205, 17215, 17225, 17250
|
11192
|
|
17250
|
Round carrier for 1 tube 50 ml no. 15049, 15050, 15056
|
13040
|
|
17225
|
Round carrier for 1 glass tube 25 ml no. 15025, 15026
|
13040
|
|
17215
|
Round carrier for 3 tubes 15 ml (round and pointed bottom) e.g. no. 15015, 150102, 15023, 125024
|
13040
|
|
17205
|
Round carrier for 4 Vacutainer tubes
|
13040
|
|
13097
|
Bucket for 1 tube 100 ml no. 15100, 15102, 15103, 15106
|
11192
|
|
13047
|
Bucket for 1 tube 50 ml no. 15049, 15050, 15056
|
11192
|
|
13022
|
Bucket for 1 glass tube 25 ml no. 15025, 15026
|
11192
|
|
13012
|
Multiple carrier for 4 tubes 15 ml no. 15015, 15020, 15023, 15024
|
11192
|
|
13004
|
Multiple carrier for 5 glass tubes 7 ml no. 15007, 15027
|
11192
|
|
13009
|
Multiple carrier for 5 RIA-tubes ø12 x 75 mm no. 15060
|
11192
|
|
13042
|
Multiple carrier for 6 x 5-15 ml 17/19x90-110, Monovettes
|
11192
|
|
13064
|
Adapter 1 x 30 ml 25/31 x 65 mm Sterilin no. 3008
|
13150
|
Technical specifications SIGMA 2-16
|
Power supply
|
100-120/50+60Hz 230V/50+60Hz
|
|
Power consumption
|
240 W
|
|
Maximum rotational speed
|
15.000 rpm
|
|
Minimum rotational speed
|
100 rpm
|
|
Maximum capacity
|
4 x 100 ml
|
|
Interference suppression
|
EN 55.011 Kl. B
|
|
Dimensions: Height x Width x Depth
|
300x365x460 mm
|
|
Weight without accessories
|
31 kg
|
|
Max. kinetic energy
|
7.756 Nm
|
|
Noise level at max. speed
|
|
Rotor 11190
|
< 67 [dB (A)]
|
|
Max. acceleration
|
|
Rotor 12148
|
30 s
|
|
Rotor 11190
|
34 s
|
|
Max. deceleration
|
|
Rotor 12148
|
23 s
|
|
Rotor 11190
|
17 s
|